Page 181 - byob-catalog
P. 181
ELECTRICAL
179
Voltage Regulator/Rectifiers B
Price
$45.22 $185.71
187 Series Circuit Breakers
0.300" 7.62mm
Reset-Only Circuit Breakers
Provides circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required. Features: Self-trimming case eliminates need for mounting panels or trim bezels. Visible yellow reset lever shows open condition. Trip-free design cannot be held closed after trip. Large clearance around terminal studs accepts up to 1/0 AWG lugs. Recessed mounting holes for clean appearance. 5/16"- 18 terminals provide high torque connections. 5,000A AIC for large battery banks. Specifications: Interrupting Capacity 5,000A @ 12V DC, 3,000A @ 24V DC, 1,500A @ 42V DC. Voltage Max. Operating 48V DC. Amperage Trip Reference See table. Temperature Min. Operating -40°C. Temperature Max. Operating 85°C. Type Thermal. Class Type III—Switchable/Manual Reset—Trip Free. Terminal Stud 5⁄16”- 18. Terminal Stud Torque 75 in-lb max. Trip Time Delay See www. bluesea.com. Mounting Hole Accepts #10 (M5) Screw. Regulatory: Meets SAE J1171 external ignition protection requirements IP66— protected against powerful water jets.
MOUNT 53.97m
A
3.386" 86.01mm
2.750" 69.85mm
2.125" 53.97mm
0.732" 18.59mm
mfr
SIE
A
B 18-5743
Part No.
Merc #
816770T 815279-3
Models
-
30-275 hp
18-5707
2.260" 57.42mm
Medium Duty Push Button BSS
mfr
Panel Mount
Panel Mount Dimensions
Part No. Each
7035 $92.99 7036 $92.99 7037 $92.99 7044 $92.99
A-Series Toggle Circuit Breakers
Amps
25A DC 30A DC 35A DC 100A DC
mfr
BSS
Provides circuit protection for 15 to 60 Amp loads when switching is provided elsewhere is not required. Features: Weatherproof. Can be used as Main or Branch. Push-to-reset operation. Trip Free design cannot be held ON during fault current condition. Captive star lock washers meet requirements for anti-rotation and eliminate handling of small, easily dropped parts. Specifications: Interrupting Capacity 5,000A @ 32V DC. 3,000A @ 120V AC. Voltage Max. Operating 32V DC / 120V AC. Temperature Min. Operating -54°C. Temperature Max. Operating 74°C. Type thermal trip, manual reset. Terminal Stud #10-32 Stainless Steel. Terminal Stud Torque 30 in-lb max. Trip Time Delay. See www. bluesea.com. Mounting Thread #8 -32: Regulatory: SAE J1428, SAE J553, UL 1077. Meets UL 1500 external ignition protection requirements.
mfr 7208 BSS
Part No. Each
7208 $22.99 7237 $52.99 7238 $52.99
7238
Part No.
2138 2139 2140 2141 2142 2143
Each
$56.34 $56.34 $56.34 $56.34 $56.34 $56.34
Amps
15A DC 20A DC 30A DC 40A DC 50A DC 60A DC
Color
Black Black White
Amps
15A 30A 30A
ST-Blade Battery Terminal Mount Fuse Block Kit
mfr
BSS
mfr
BSS
Part No. Each
5191 $28.49
Battery Terminal Mount
Easy to install 4 ATO®/ATC® fused circuits. Mounts on the battery terminal stud. Screw terminals for securing wires. Four Nylon insulated ring terminals included. Insulating cover included. Accepts Small Format Circuit Labels. Includes 1 fuse.
Part No. Each
5024 $39.99
Stud Size Mounting
M8 (5/16"-18) 3/8"
Fuses
1
S
TERMINAL BLOCKS, BUSBARS, CIRCUIT BREAKERS PLUGS & RECEPTACLES, FUSE BLOCKS, FUSES